by
Anonymous Coward
on 2023年09月14日 22時08分
(#4529333)
ストーリーからリンクを貼ってるロイターの記事にこう書いてある。
The ANFR said accredited labs had found absorption of electromagnetic energy by the body at 5.74 watts per kilogram during tests simulating when the iPhone 12 was being held in the hand or kept in a trouser pocket. The European standard is a specific absorption rate of 4.0 watts per kilogram.
ANFR added the tests showed the phone complied with so-called body-SAR standards when it was in a jacket pocket or bag. It also passed the French tests when held directly to the head as if making a phone call.
問題ない (スコア:1)
持ち方が悪いだけ
Re:問題ない (スコア:0)
ストーリーからリンクを貼ってるロイターの記事にこう書いてある。
The ANFR said accredited labs had found absorption of electromagnetic energy by the body at 5.74 watts per kilogram during tests simulating when the iPhone 12 was being held in the hand or kept in a trouser pocket. The European standard is a specific absorption rate of 4.0 watts per kilogram.
ANFR added the tests showed the phone complied with so-called body-SAR standards when it was in a jacket pocket or bag. It also passed the French tests when held directly to the head as if making a phone call.
つまり、フランスの主張では、胴体テスト(上限4W/kg)を
・上着のポケット
・鞄の中
で行った場合は合格してるが、
・手で持つ
・ズボンのポケット
で行った場合は基準値をオーバーしている。
これとは別に、頭部テスト(上限2W/kg)もあるが(おそらく電波の発信位置と通話姿勢での頭部の距離が十分に遠いから)、これには合格している。別の言い方をすると、iphone12だと手で持つのはおろか、ズボンのポケットに入れるのも体に近すぎる。
Re: (スコア:0)
近接センサー出力制限してると思うけどその辺の制御がうまくいってないのかもね。
6分平均のギリギリ狙ってるとか。